This message retrieves the minimum and maximum positions, or the range, for an up-down control.

Syntax

UDM_GETRANGE 
wParam = 0; 

lParam = 0;

Parameters

wParam

Not used.

lParam

Not used.

Return Value

The return value is a 32-bit value that contains the minimum and maximum positions. The low-order word is the maximum position for the control, and the high-order word is the minimum position.