Previous Topic

Next Topic

Logical Drive X Status = Wrong Drive Replaced

Description: A physical drive in this logical drive has failed. The incorrect drive was replaced.

Action:

  1. Power down the server.
  2. Replace the drive that was incorrectly replaced.
  3. Replace the original drive that failed with a new drive.

    CAUTION: Do not run the server setup utility and try to reconfigure, or data will be lost.